JUMO Logo
  • Team Sales

    Technical consulting & individual offers

    +39 02 24 13 55 1
    automation
    +39 02 24 13 55 1
    sensors
    Team Support

    Troubleshooting

    +39 02 24 13 55 1
    Support
    Team Engineering

    Individual products developments & innovations

    +39 02 24 13 55 1
    Engineering
    • Germany
      • German
      • English
    • Switzerland
      • German
      • English
    • Poland
      • Polish
      • English
    • Netherlands
      • Dutch
      • English
    • Sweden
      • Swedish
      • English
    • Belgium
      • Dutch
      • French
      • German
      • English
    • France
      • French
      • English
    • Austria
      • German
      • English
    • Spain
      • Spanish
      • English
    • Italy
      • Italian
      • English
    • Slovenia
      • English
    • Croatia
      • English
    • Serbia
      • English
    • Bosnia
      • English
    • Hungaria
      • English
    • USA
      • English
    • United Kingdom
      • English
    • Czech Republic
      • Czech
      • English
    • China
      • Chinese
  • 0
  • Search for

    Are you looking for suitable products for a specific application? Start product selection guide

  • Products
    • Product Highlights
    • Temperature
      • Automation
      • Paperless recorders
      • Digital indicators
      • Transmitters
      • Platinum temperature sensors Pt100, Pt1000
      • Controllers
      • Switches
      • Thermocouples
      • Thermostats
      • Monitors & limiters
      • Heat meters
      • RTD temperature probes
      • Dial thermometers
      • Contact dial thermometers
      • Accessories
    • Liquid analysis
      • Automation system
      • Electrodes & Sensors
      • Transmitter & Controllers
      • Accessories
    • Pressure
      • Automation system
      • Digital indicators
      • Transmitters
      • Measuring cells
      • Control
      • Accessories
    • Humidity & CO2
      • Automation system
      • Hygrostats
      • Hygro transducers and hygrothermal transducers
    • Flow
      • Automation system
      • Paperless recorders
      • Digital indicators
      • Measuring devices
      • Controllers
      • Flow sensor
    • Level
      • Automation system
      • Paperless recorders
      • Digital indicators
      • Transmitters
      • Level sensors
      • Level probes
      • Controller
      • Float switches
    • Actuator
      • Semiconductor relay
      • Power control
    • Product selector
    • Product list A-Z
  • Applications
    • All applications at a glance
    • Food and beverage
      • Beer production
      • CIP cleaning
    • Water and wastewater
      • Ground water treatment
      • Swimming pool water treatment
      • Cooling water treatment
    • Railway technology
      • Diesel propulsion
      • Chassis technology
      • Climate control
      • Water supply
    • Hydrogen
    • Aquaculture
    • Industrial furnace construction
      • Continuous heat treatment process
      • Discontinuous heat treatment process
    • Heating and air-conditioning technology
      • Air-conditioning technology
      • Heating technology
      • Heat and cold meters
    • Shipbuilding industry
      • Tank ship
      • Water treatment
      • Heating and cooling systems
  • Services
    • Download center
    • Product archive
    • Frequently asked questions
    • Special production
      • Customer-specific sensor technology
      • Electronic modules
      • Metal technology
    • Commissioning
      • Field service
      • Configuration service
    • Calibration
      • DAkkS calibration
      • Temperature calibration
      • Pressure calibration
      • Humidity calibration
      • On-site calibration
    • Maintenance
      • Spare parts
      • Repair services
      • Returns
      • Technical support
      • Maintenance contracts
    • Trainings
      • Seminars
      • Exclusive trainings
      • Webinars
      • E-Learnings
    • Electronic data exchange
      • BMEcat
      • EPLAN
  • About Us
    • Profile and focus
    • Expertise and strengths
    • Development partnership
    • Success stories
    • Quality standard
    • Locations worldwide
    • Contact
    • Fair dates
    • Management
    • History
    • Social responsibility
      • Environment and safety
      • Regional responsibility
      • Responsible export
    • Current topics
      • News
      • Software Newsletter
      • Newsletter
      • Customer magazine
      • Company information
    • Imprint
    • Terms and conditions
    • Privacy policy
  • Germany
    • German
    • English
  • Switzerland
    • German
    • English
  • Poland
    • Polish
    • English
  • Netherlands
    • Dutch
    • English
  • Sweden
    • Swedish
    • English
  • Belgium
    • Dutch
    • French
    • German
    • English
  • France
    • French
    • English
  • Austria
    • German
    • English
  • Spain
    • Spanish
    • English
  • Italy
    • Italian
    • English
  • Slovenia
    • English
  • Croatia
    • English
  • Serbia
    • English
  • Bosnia
    • English
  • Hungaria
    • English
  • USA
    • English
  • United Kingdom
    • English
  • Czech Republic
    • Czech
    • English
  • China
    • Chinese
{}
start portlet menu bar
Display content menu Display portlet menu
end portlet menu bar
Type 202540

JUMO dTRANS Lf 01

start portlet menu bar
Display content menu Display portlet menu
end portlet menu bar

What is to be taken into account for the error messages F022 and F023?

The error messages F022 and F023 indicate that the measuring range is gone below or exceeded.
Hold is additionally displayed. In this case, we recommend to check the correct actual value recording.
Check the measuring cell, cables, connectors and the set measuring range "ranG“ with the cell constant specified on the measuring cell.

start portlet menu bar
Display content menu Display portlet menu
end portlet menu bar

An 'ERR' error message appears on the device.

Calibration of the relative cell constant or determination of the temperature coefficient of the medium to be measured was completed with an error. The previous data is saved.
The factory data is displayed (Cell = 100%, ALPH= 2.3).
To remedy the 'ERR' error message, manually change the two parameters using the keyboard (e.g. change by one digit up or down and confirm with the PGM key) or re-calibrate the system.

start portlet menu bar
Display content menu Display portlet menu
end portlet menu bar

An actual value output is required - What is to be taken into account?

Ensure that the device is equipped with the respective analog output. For this purpose, check the type designation of the device.
Refer to chapter 4.1, Type explanation, in the operating instructions.

0.284

Configuration level C213 - Other outputs I is set.
Actual value output 2 is set in configuration level C214 - Other outputs II.
The scaling is set under the parameters SOL and SOH.

start portlet menu bar
Display content menu Display portlet menu
end portlet menu bar

I cannot change settings in the parameter level and the configuration level.

To be able to carry out settings in the two levels, enter the respective CODE for activation first.
Start situation > Measuring mode > Repeatedly press the PGM key until CODE appears. Set the respective CODE by pressing the UP/DOWN keys. Press the PGM key to confirm.
The display returns to 0000. Now, the corresponding level (parameter) can be selected. The code has been entered correctly when the decimal point flashes during entry.

Function Code
Unlock the operator level, CAL and manual activation of Hold. 0110
Unlock the operator and parameter level. 0220
Unlock all levels. 0300

 

start portlet menu bar
Display content menu Display portlet menu
end portlet menu bar

Is it possible to change the switching behavior of N/C / N/O

The setting N/O / N/C for the two contacts K1 and K2 can be changed in the configuration level under point C212 (controller outputs).
Both contacts are factory set to NOC.
NOC: (N/O) The corresponding output is active (closed) as long as the switching condition is fulfilled.
NCC: (N/C) The corresponding output is active (closed) as long as the switching condition is not fulfilled.

start portlet menu bar
Display content menu Display portlet menu
end portlet menu bar

What does Min/Max contact mean?

The configuration level C212 (controller outputs) can be used to change the Min/Max behavior for the two contacts K1 and K2.
MIN contact: The switching condition is fulfilled when the actual value is lower than the set point value.
MAX contact: The switching condition is fulfilled when the actual value exceeds the set point value.

0.2AC


start portlet menu bar
Display content menu Display portlet menu
end portlet menu bar

How to check the correct function (actual value display) of the device and the cable?

The actual value can be preset by an Lf simulator. If the simulator is not available, it is possible to connect a resistance via a fixed resistor to the two input terminals of the device and, to check the cable, to the end of the cable.
The actual value can be read on the device according to the resistance.
The required resistance can be calculated using a formula.
The device should have factory settings and should not display any error message.

For example:
Measuring range 0...100uS
Desired displayed value 50uS
Cell constant K=0.1

P1_3_Q1

 

R (measuring cell resistance) = 0.01 (cell constant K)
                                                     5 uS (desired displayed value)
This results in a measuring cell resistance R of 2000 Ohm, which has to be connected to the two terminals 6 and 7.

start portlet menu bar
Display content menu Display portlet menu
end portlet menu bar

How to start the calibration process?

To be able to start calibration, activate the controller.
Start situation > Measuring mode > Repeatedly press the PGM key until CODE appears > Enter 0300 and confirm with PGM > Press the Exit key once > Simultaneously press the PGM + Down key.
A temperature of 25.0 appears in the top (red) display, °C appears in the bottom (green) display, the decimal point in the bottom display flashes. Refer to the operating instructions for the further procedure.

start portlet menu bar
Display content menu Display portlet menu
end portlet menu bar

Our services for you

Thermocouple

For water, oil or air
Configure now!

Engineering

Custom fit and individual
Get advice now!
CONTACT

JUMO Italia SRL
Via Carducci, 221/54
20099 Sesto San Giovanni MI

Phone: +39 02 24 13 55 1
Fax: +39 02 24 30 84 22
Email: info.it@jumo.net

  • Imprint
  • Privacy policy
  • General Terms of Business Relations
QUICKLINKS
  • JUMO Customer magazine
  • JUMO Campus
FOLLOW US
YouTubeFacebookLinkedInTwitterInstagram
More than Sensors + Automation
Imprint
Privacy policy
General Terms of Business Relations
Complementary Content Deferred Modules
  • ${title}${badge}
${loading}
Deferred Modules