Sensors for conductive conductivity measurement

Conductive measurement is a widely used principle for acquiring the conductivity of liquids. JUMO offers a variety of high-quality conductivity sensors for a wide variety of applications. These include compact and separate design types with 2 or 4 electrodes and with digital interfaces such as JUMO digiLine or IO-Link. See for yourself!

  • Product selection guide

Sensors for conductive conductivity measurement

Filter
1
Hits: 15
JUMO tecLine CR-GT - Conductive two-electrode conductivity sensor

JUMO tecLine CR-GT

Conductive two-electrode conductivity sensor Basic type: 202925
These sensors are used in conjunction with conductivity transmitters to define the electrolytic conductivity in liquids. They are especially suitable for media separation, drinking water preparation, and for inspecting as well treating wastewater and service water.
  • Measuring range: 10 µS/cm to 15 mS/cm
  • Process pressure up to 16 bar
  • Cell constant K = 1.0
JUMO tecLine CR - Conductive two-electrode conductivity sensor

JUMO tecLine CR

Conductive two-electrode conductivity sensor Basic type: 202924
These sensors are used in conjunction with conductivity transmitters to define the electrolytic conductivity in liquids. The materials in the sensors are physiologically harmless and meet FDA requirements.
  • Measuring range: 0.05 µS/cm to 1 mS/cm
  • Process pressure up to 16 bar
  • Cell constant K = 0.01 or 0.1
JUMO tecLine CR S01 - Conductive two-electrode conductivity sensor

JUMO tecLine CR S01

Conductive two-electrode conductivity sensor Basic type: 202928
The compact design type of the conductive two-electrode conductivity sensor enables space-saving installation. Due to its wide measuring range and resistance to cold, heat, and pressure, it is ideally suited for many applications in water treatment and monitoring.
  • Measuring range: 0.1 to 5000 µS/cm
  • Process pressure up to 6 bar
  • Cell constant: K = 0.1 or 1.0
JUMO BlackLine CR 4P - Conductive 4 Electrode Conductivity Sensor

JUMO BlackLine CR 4P

Conductive 4 Electrode Conductivity Sensor Basic type: 202931
The conductivity sensor has 4 electrodes made of robust special graphite and is characterized by a wide measuring range. It is therefore predestined for determining the conductivity of high salt concentrations. This is why it can be used in salt and sea water applications, among others.
  • Measuring range: 1 µS/cm to 300 mS/cm
  • Process pressure up to 6 bar
  • Cell constant: K = 0.25
JUMO digiLine CR HT30 - Head transmitter with conductive two-electrode conductivity sensor type VA

JUMO digiLine CR HT30

Head transmitter with conductive two-electrode conductivity sensor type VA Basic type: 202765
JUMO digiLine CR now enables conductive conductivity sensors to be connected to the intelligent, bus-compatible JUMO digiLine system. System integration can now also take place via an IO-Link interface. The sensor is firmly connected to the head transmitter.
  • Compact design type with conductive sensor
  • Measuring range: 0.05 µS/cm to 1 mS/cm
  • JUMO digiLine or IO-Link interface
JUMO digiLine CR HT40 - Head transmitter with conductive two-electrode conductivity sensor type SL

JUMO digiLine CR HT40

Head transmitter with conductive two-electrode conductivity sensor type SL Basic type: 202766
JUMO digiLine CR now enables conductive conductivity sensors to be connected to the intelligent, bus-compatible JUMO digiLine system. System integration can now also take place via an IO-Link interface. The sensor is firmly connected to the head transmitter.
  • Compact design type with conductive sensor
  • Measuring range: 0.05 µS/cm to 1 mS/cm
  • JUMO digiLine or IO-Link interface
JUMO digiLine CR HT50 - Head transmitter with conductive two-electrode conductivity sensor type PK

JUMO digiLine CR HT50

Head transmitter with conductive two-electrode conductivity sensor type PK Basic type: 202767
JUMO digiLine CR now enables conductive conductivity sensors to be connected to the intelligent, bus-compatible JUMO digiLine system. System integration can now also take place via an IO-Link interface. The sensor is firmly connected to the head transmitter.
  • Compact design type with conductive sensor
  • Measuring range: 0.05 µS/cm to 1 mS/cm
  • JUMO digiLine or IO-Link interface
JUMO digiLine CR HT60 - Head transmitter with conductive two-electrode conductivity sensor type GT

JUMO digiLine CR HT60

Head transmitter with conductive two-electrode conductivity sensor type GT Basic type: 202768
JUMO digiLine CR now enables conductive conductivity sensors to be connected to the intelligent, bus-compatible JUMO digiLine system. System integration can now also take place via an IO-Link interface. The sensor is firmly connected to the head transmitter.
  • Compact design type with conductive sensor
  • Measuring range: 10 µS/cm to 15 mS/cm
  • JUMO digiLine or IO-Link interface
JUMO digiLine CR HT70 - Head transmitter with conductive four-electrode conductivity sensor type 4P

JUMO digiLine CR HT70

Head transmitter with conductive four-electrode conductivity sensor type 4P Basic type: 202769
JUMO digiLine CR now enables conductive conductivity sensors to be connected to the intelligent, bus-compatible JUMO digiLine system. System integration can now also take place via an IO-Link interface. The sensor is firmly connected to the head transmitter.
  • Compact design type with conductive sensor
  • Measuring range: 1 µS/cm to 600 mS/cm
  • JUMO digiLine or IO-Link interface
JUMO digiLine CR HT20 - Head transmitter with conductive two-electrode conductivity sensor type PVC

JUMO digiLine CR HT20

Head transmitter with conductive two-electrode conductivity sensor type PVC Basic type: 202764
JUMO digiLine CR now enables conductive conductivity sensors to be connected to the intelligent, bus-compatible JUMO digiLine system. System integration can now also take place via an IO-Link interface. The sensor is firmly connected to the head transmitter.
  • Compact design type with conductive sensor
  • Measuring range: 0.1 µS/cm to 15 mS/cm
  • JUMO digiLine or IO-Link interface
JUMO digiLine CR HT10 - Head transmitter with conductive two-electrode conductivity sensor type EC

JUMO digiLine CR HT10

Head transmitter with conductive two-electrode conductivity sensor type EC Basic type: 202763
JUMO digiLine CR now enables conductive conductivity sensors to be connected to the intelligent, bus-compatible JUMO digiLine system. System integration can now also take place via an IO-Link interface. The sensor is firmly connected to the head transmitter.
  • Compact design type with conductive sensor
  • Measuring range: 0.1 µS/cm to 100 mS/cm
  • JUMO digiLine or IO-Link interface
JUMO digiLine CR ST10 - Transmitter for separate conductive conductivity sensor

JUMO digiLine CR ST10

Transmitter for separate conductive conductivity sensor Basic type: 202762
JUMO digiLine CR now enables conductive conductivity sensors to be connected to the intelligent, bus-compatible JUMO digiLine system. In addition to the JUMO digiLine interface, system integration can now also take place via an IO-Link interface.
  • Separate design type for conductive sensors
  • Measuring range: 0.05 µS/cm to 600 mS/cm
  • JUMO digiLine or IO-Link interface
JUMO ecoLine CR-PVC - Conductive two-electrode conductivity sensor

JUMO ecoLine CR-PVC

Conductive two-electrode conductivity sensor Basic type: 202923
Conductivity sensors of this type series are used, among other areas, in general water technology, cooling and air conditioning system technology, drinking water and swimming pool water sectors, and in industrial rinsing and process water circuits. The electrode material is stainless steel or special graphite.
  • Measuring range: 0.05 µS/cm to 15 mS/cm
  • Process pressure up to 6 bar
  • Cell constant: K = 0.1 or 1.0
JUMO BlackLine CR-GT/-EC/-GS - Conductive two-electrode conductivity sensor

JUMO BlackLine CR-GT/-EC/-GS

Conductive two-electrode conductivity sensor Basic type: 202922
The product is available in versions GT, EC, and GS. A special graphite is used in the GT version for water treatment. The main features of the stainless steel EC version are its very compact design type and the integrated Pt100 as a standard feature.
  • Measuring range: 0.05 µS/cm to 100 mS/cm
  • Process pressure up to 6 bar
  • Cell constant: K = 0.01; 0.1 or 1.0
JUMO tecLine CR-4P - Conductive four-electrode conductivity sensor

JUMO tecLine CR-4P

Conductive four-electrode conductivity sensor Basic type: 202930
These conductivity sensors are suitable for the measurement of electrolytic conductivity in aqueous solutions. In contrast to customary two-electrode sensors, they offer application-related advantages in the range between medium and high conductance.
  • Measuring range: 1 µS/cm to 600 mS/cm
  • Process pressure up to 16 bar
  • Cell constant K = 0.3 to 0.4

item items, maximum number of items reached